Power at L1B and L2B passes through the circuit breaker switch located on the left side of the
control housing.
There are five programmable “Form A” (SPST-NO) solid state relay outputs rated at 500mA up
to 40 VDC.
-
Out 1 (K9)
-
Out 2 (K8)
-
Out 3 (K7)
These five outputs can be wired as NPN or PNP. The output can be set to NO or NC under
normal running conditions.
REJECT
Reject (K1) is the primary reject device output. It must run via Reject Timer or Overhead A-B
when used. All reject log information is based on Reject Timer.
RELAY 1-3
Relay 1(K3), Relay 2 (K2), and Relay 3 (K4) are fully programmable and may use any of the
four reject timers. They also may use Overhead A-B or be used as a fault or warning output.
See
for details regarding I/0 configuration.
OUT 1-5
Out 1 (K9), Out 2 (K8), Out 3 (K7), Out 4 (K6), and Out 5 (K5) are fully programmable and may
use any of the four reject timers. They also may use Overhead A-B or be used as a fault or
warning output.
TIMERS
There are four independent reject timers. Each reject timer has its own travel (delay) time and
reject (duration) time in the range of 0 to 60 seconds or 0 to 1200 tachometer pulses. Each
reject timer runs off of time or tach for both travel and duration time. Only Reject Timer can use
reject confirmation, a reject index device or be configured for manual reset.
FAULT
All outputs except Reject (K1) can be configured as a fault output.
WARNING
All outputs except Reject (K1) can be configured as a warning output.
-
Out 4 (K6)
-
Out 5 (K5)
SPECS
10
Summary of Contents for Xtreme
Page 2: ......
Page 8: ...6 ...
Page 31: ...FIGURE 1 TERMINAL CONNECTIONS FIGURE 2 TERMINAL CONNECTIONS ELEC 29 ...
Page 33: ...FIGURE 4 OUTPUT CONNECTION EXAMPLES ELEC 31 ...
Page 34: ...FIGURE 5 INPUT CONNECTION EXAMPLES ELEC 32 ...
Page 94: ...PLC 92 ...
Page 95: ...PLC 93 ...
Page 96: ...PLC 94 ...
Page 97: ...PLC 95 ...
Page 98: ...PLC 96 ...