Vertical Actuator Shocks - 10” System
VMD
Adjusting return shock on 10” units (Cont’d)
1. Push the door to the return position.
2. Adjust the door so the return door seal is just under the valve top.
3. Start with one of the two return shocks
4. Adjust one return shock until the door is in the proper position.
5. Once the first return shock is set, adjust the second return shock to match its position.
6. The goal is for both shocks to resist the door equally.
7. Once the door position is set push the O-ring against the actuator.
8. Push the sealing washer against the actuator.
9. Tighten the shock nut while holding the shock in position with an Allen wrench.