1. On the task bar press “Verification
Needed”.
2. Press the metal type you wish to test.
3. Pass the listed metal on the product
through the aperture and press the “Stop”
button.
4. Select Pass, Fail, or Retry and repeat the
process if necessary for the other metals.
5. “B Detection” indicates that a boundary
detection occurred. The “B” matches the
indicator placed in the reject log for
boundary detections.
6. Press “Verification Complete” when all
metals have been tested.
1
2
3
4
6
UI
“HOW TO” PERFORM A VERIFICATION CHECK
5
Test Count.
Only shown if
Tests per count
is greater than 1
Test Count.
Only shown if
Tests per count
is greater than 1
80
Summary of Contents for Xtreme
Page 2: ......
Page 8: ...6 ...
Page 31: ...FIGURE 1 TERMINAL CONNECTIONS FIGURE 2 TERMINAL CONNECTIONS ELEC 29 ...
Page 33: ...FIGURE 4 OUTPUT CONNECTION EXAMPLES ELEC 31 ...
Page 34: ...FIGURE 5 INPUT CONNECTION EXAMPLES ELEC 32 ...
Page 94: ...PLC 92 ...
Page 95: ...PLC 93 ...
Page 96: ...PLC 94 ...
Page 97: ...PLC 95 ...
Page 98: ...PLC 96 ...