background image

http://www.facebook.com/OlympiaElectronics
http://twitter.com/olympiaelectro
http://www.linkedin.com/company/1967613?trk=tyah
http://www.youtube.com/channel/UCIINc4DGSYH_0loHJqwsgoQ
https://plus.google.com/105672704483774116420/posts
http://www.olympia-electronics.gr

GENERAL

BS-695

 

and

 

BS-694

 

detectors are used to give 

us a quick warning in case there is a natural gas 
or LPG gas leak.
The  installation  must  be  done  by  a  qualified 
personnel. The instructions must be read first   
before the installation.

Emergency actions

It  is  recommended  that  the  following  advice 
should  be  given  in  the  event  of  an  alarm 
sounding or the smell of gas even without an 
alarm:
Keep calm, and carry out the following actions, 
not  necessarily  in the order given:
-  extinguish  all  naked  flames,  including 
smoking material.
 - turn off all gas appliances.
-  do  not  switch  on  or  off  any  electrical 
equipment,  including    the  gas  detection 
apparatus.
-  turn off the gas supply at the gas main control 
and/or ( with a LPG supply) the storage tank.
-  open  doors  and  windows  to  increase 
ventilation;
- do not use a telephone in the building where 
the presence of a gas is suspected.
If the alarm continues to operate, even after an 
alarm resetting action where appropriate, and 
the  cause  of  the  leak  in  not  apparent  and/or 
cannot be corrected, vacate the premises and 
IMMEDIATELY  NOTIFY  the  gas  supplier    in 
order  that  the  installation  may  be  tested  and 

made  safe,  and  any  necessary  repair  carried 
out.

Placement

Depending on the monitored gas, the unit must 
be placed 30cm from the ceiling (for methane, 
natural gas) or 30cm from the floor (for propane, 
butane, LPG).   The horizontal distance should 
not be more than 4 meters from the probable 
gas  leak  point  and  the  detectors  must  not  be 
placed in humid or drafty areas.
It  is  suggested  that  the  detector  is  tested  for 
good  operation  every  6  months  or  if  it  is 
changed position.
The unit must should not be sited:
- directly above cooking appliances.
- directly above sink.
- adjacent to extractor fans.
- in any outside location.
-  where  the  environmental  conditions  are 
outside  the  manufacturers  operational 
specification.

Installation

For the installation of the device first you must 
remove  the  red  plastic  with  a  screwdriver  as 
shown in figure 1 and unscrew  the screw in the 
middle. Then with the help of figure  2  you can 
connect the  external devices.

Sensitivity

The BS-694

 

detectors are activated when the 

220-240V AC/50-60Hz

Yes

Yes

Relay

 (230

V AC, 

5Α)

Power LED , alarm LED 

,

 fault LED

IP40

  5 years

EN 50194, EN 61000-3-2, EN 61000-3-3

o

0

 to 

6

0  C

Up to 95% 

No

No

5-15 % L.E.L. 

Propane

5-15 % L.E.L. 

Methane

145 x 85 x 45 mm

Bayblend FR3010

BS

-694

BS

-69

5

4

VA

TECHNICAL CHARACTERISTICS

 

OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIALS 
EXTERNAL DIMENSIONS 
TYPICAL WEIGHT
GUARANTEE 

OPERATION VOLTAGE
AVERAGE POWER CONSUMPTION
SENSITIVITY

OUTPUTS
ELECTRO VALVE OUTPUT
EXTERNAL BUZZER OUTPUT
SENSOR LIFETIME

INDICATIONS

DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH

2

 years

27

0gr.

BS-694                 Autonomous LPG detector

BS-695         Autonomous natural gas-methane detector

Page 

1

 from

 

4

Thank you for your trust in our products.  

Olympia Electronics -  European manufacturer

.

921695000

_09_009

Reviews: