IndexIndex
12.3
Warning Severity Alarms
12.3.1
ElnLinkDown
MIB:
ERICSSONELNTRAPMIB
Description
: A link to one of the ports is not operational.
Corrective Actions
:
Ensure that the node connected to the other end of the link is operational.
Check the physical link (optical or electrical) for damage and replace if
necessary.
Valid from EDA 2.2 R3A
Parameters:
No. Parameter
Parameter Value
1
Managed object
class
EFN324fport
or
ELN220port
2
Managed object
Instance
EFN324=<
IP address
>,port=<
no.
>
or
ELN220=<
IP address
>,port=<
no.
>
3
Sequence number
Alarm sequence number
4
Perceived severity
Warning
5
Event time
Time stamp from real time clock retrieved
through a SNTP server
6
Event type
CommunicationsAlarm
7
Probable cause
terminalProblem
Clearing Alarms
Linkup, ElnRestart
Summary of Contents for EFN324
Page 1: ...EFN324 User Guide EDA 1200...
Page 4: ...Error No text of specified style in document Glossary 168 Index 170...
Page 176: ......