Glossary
4. Connect the new EFN324 to the network, and connect the power supply.
5. Use the PEM Synchronize function to download the configuration data to
the EFN324.
The replacement of the standalone EFN324 is now completed.
11.2.2
Replacing an Embedded EFN324
If PEM is used, an embedded EFN324 cannot be replaced with another
EFN324 of a different type. For example, an embedded EFN324f cannot be
replaced with an EFN324df.
To replace an embedded EFN324, do the following:
1. Remove the power supply from the old EFN324.
2. Remove the EFN324 from the network.
3. Do the initial configuration for an embedded EFN324, using the same
flexible block ID (also known as Switch ID), management VLAN and
(optionally) multicast VLANs as the EFN324 that is being replaced. The
initial configuration for an embedded EFN324 is described in detail in the
EFN324 Installation Guide
.
4. Connect the new EFN324 to the network, and connect the power supply.
5. The EMP gives the new EFN324 the same IP address as the old EFN324.
The EMP then sends the saved copy of the EFN324 configuration file to
the EFN324.
The replacement of the embedded EFN324 is now completed.