IndexIndex
Arguments:
File name –
The name of the configuration file. Note that the
configuration file that PEM has configured is named
primary
.
Default Setting
None.
Command Usage
When using this command, the currently permanent configuration file, if any,
will lose its status of being permanent.
Example:
efn#
config make_permanent test
13.9.6
set main_board
Use this command to set the alarm limit for the temperature of the main board.
Use the command
reset main_board
to reset to default values.
Syntax
set main_board temperature_limit <limit>
Arguments:
<limit> –
Limit for the temperature, setting when a temperature alarm
is issued. Range 20 to 80 °C.
Default Setting
80
Example:
efn#
set main_board temperature_limit 50