connect vlan 130 ethernet_port 1 ingress tags 700 flow_selector none egress tag 700 p_tag 5
connect vlan 130 ethernet_port 25 ingress tags 700 flow_selector none egress tag 700 p_tag 5
set connection_flow vlan 130 ethernet_port 1, 25 ingress flow 1 priority high reliability high
With this configuration, the traffic from the business users, from VLAN 500 is
handled as:
frames tagged with pbit 0 or 1 will be headed to flow 1; the marking in
QoSFlow_1 is defined Transparent, frames will exit with the original p
tag, i.e. pbit = 0 or pbit = 1
frames tagged with pbit 2 or 3 will be headed to flow 2; the marking in
QoSFlow_2 is defined Transparent, frames will exit with the original p
tag, i.e. pbit = 2 or pbit = 3
frames tagged with pbit 4, 5 will be headed to flow 3; the marking in
QoSFlow_3 is defined marking 4, so frames will exit with the modified
pbit = 4
frames tagged with pbit 6, 7 will be headed to flow 4; the marking in
QoSFlow_4 is defined marking 6, so frames will exit with the modified
pbit = 6
For residential users, all traffic on VLAN 600 shall be remarked with pbit = 0,
while all traffic on VLAN 700 shall be remarked with pbit = 5.
5.6.2
Examples 2: trusted and untrusted users configuration
This example describes a 3play configuration where traffic on the user side is
single tagged and on the network side is double tagged; in the upstream
direction the added tag will inherit the pbit tag from the user’s tag.
Global Setting:
set connection_flow node_level flow 1 priority low reliability low marking transparent
set connection_flow node_level flow 2 priority low reliability low marking transparent