4.14.10 LED Lighting Test
EXECUTION MODE
Serviceman Mode
PROCEDURE
1.
Turn the printer ON in the Serviceman Mode.
Turn the power ON while pressing
[RIGHT] + [DOWN] + [OK]
.
2.
Confirm the Power Light lights.
3.
Select
[SELF TESTING]
→
[Mecha Adjustment]
→
[Panel Check]
.
4.
Confirm the “Error Light” and “Start Light” light up.
Figure 4-96. Buttons and Display of the Control Panel
Start Light
Power Light
Error Light