SC-F2000
Revision C
DISASSEMBLY & ASSEMBLY
Disassembly and Assembly Procedure
123
Confidential
3.4.5.5 CR SCALE
1.
2.
Disengage the CR Scale Spring from the hook on the left side of the Main Frame.
3.
Remove the CR Scale Spring from the CR SCALE.
4.
Disengage the CR SCALE from the hook on the right side of the Main Frame.
5.
Pull out the CR SCALE from the CR UNIT.
Figure 3-87. Removing the CR SCALE
A D J U S T M E N T
R E Q U I R E D
When replacing/removing this part, refer to
Items and the Order by Repaired Part”
perform the specified operations including required adjustment.
Attach the CR SCALE with the marking on the top left corner
(See
).
Go through the CR SCALE through the detection point on the
CR ENCODER on the rear of the CR UNIT when installing it.
Side view
CR SCALE
CR ENCODER
Detection point
CR UNIT
Left side
CR Scale Spring
Marking
Hook
Right side
Hook
CR UNIT