11. Release the cable from the clamp.
12. Disconnect the cable from the connector of the POWER SUPPLY BOARD.
13. Loosen the two screws.
C) Silver M3x6 Cup S-tite screw: 2 pcs
14. Remove the four screws, and remove the PS Shield Plate Assy to the rear.
D) Silver M3x6 Cup S-tite screw: 2 pcs
Figure 3-46. Removing the PS Shield Plate Assy
C H E C K
P O I N T
When loosen the screw C, use a stubby screwdriver. To loosen the
screw C easily, first remove the PUMP CAP ASSY
then
insert the screwdriver into the hole on the frame shown below to
reach the screw.
Hole
Screwdriver
D
D
C
C
Clamp
Cable
Connector
PS Shield Plate Assy