TROUBLE SHOOTING
Remedies for Service Call Error
44
Confidential
D390
USB memory access
error
Abnormality of memory access. Occurs during
reading/writing data at the following operations.
At power-on
When inserting/removing a USB flash drive
When saving data
When printing data
When displaying thumbnails
Check if the error recurs.
1. Restart the printer.
2. Replace the USB flash drive with another one.
D197
Print driving finish wait
timeout error
Occurs when CR UNIT cannot detect the print
start position.
Contamination or scratches on CR SCALE
Contamination or damage of CR ENCODER
Contamination on CR shaft
Too much load for the CR UNIT operation
1. Check if there is any foreign material inside the
printer.
2. Check if CR SCALE is scratched or contaminated.
3. Check the reading status of CR ENCODER using
Service Program.
4. Check if there is any foreign material in the driving
path of CR UNIT.
5. Check if grease on OIL PAD of CR UNIT has dried
out.
1. Remove the foreign material.
2. Clean CR SCALE with ethanol.
3. Replace CR SCALE if damaged.
4. Replace the CR ENCODER (CR UNIT).
5. Lubricate the OIL PAD.
----
Interlock switch
communication error
Communication failure due to broken cables.
1. Various Service Call Errors are displayed in turn
inconsistently. (e.g.: 1138 => 1411 => 1418 =>
150C, etc.)
2. Is the cable of the INTERLOCK SWITCH broken?
Replace the INTERLOCK SWITCH.
Code
Error Name
Cause
Check Item
Remedy
Summary of Contents for SC-F2000 Series
Page 1: ...SC F2000 Direct To Garment Printer SERVICE MANUAL SECP13002 Confidential ...
Page 10: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 29: ...Confidential C H A P T E R 2 TROUBLESHOOTING ...
Page 52: ...Confidential C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Page 192: ...Confidential C H A P T E R 4 ADJUSTMENT ...
Page 285: ...Confidential C H A P T E R 5 MAINTENANCE ...