SC-F2000
Revision C
MAINTENANCE
Lubrication
299
Confidential
[Lubrication 11]
[Lubrication 12]
Part Name
PG Change Lever
Lubricants (Part Code) G-26 (1080614)
Amount
1.
φ
2 mm
×
5 mm
×
3 points
2.
φ
2 mm
×
8 mm
×
3 points
Lubrication Tool
φ
2 mm injector
Lubrication Manner
1. Apply the lubricant into the groove on the upper side of the PG
Change Lever.
2. Apply the lubricant on the back of the PG Change Lever every 120
°
.
Note
Be careful not to apply the lubricant beyond the specified point.
Back
Lubrication
Point
Lubrication
Point
Upper
PG Change Lever
Lubrication
Point
Lubrication
Point
Lubrication
Point
Lubrication
Point
Part Name
PG Assy Flange
Lubricants (Part Code) G-26 (1080614)
Amount
φ
2 mm
×
2 mm
×
3 points
Lubrication Tool
φ
2 mm injector
Lubrication Manner
Apply the lubricant on the outer part of the PG Assy Flange every 120
°
.
Note
Be careful not to apply the lubricant beyond the specified point.
PG Assy Flange
Lubrication
Point
Lubrication
Points