2.2.1.3 Interrupt Control
The ASIC E05A93 determines the priority level of the interrupt and outputs it to terminals IRL0 -
IRL3. Then an interrupt is sent to the CPU. When the IRL0-3 value is 1111B, the CPU process is a
non-maskable interrupt process. When the IRL0-3 value is 0000B, the CPU process is a standard
process. When the IRL0-3 is any other value, the CPU process is a maskable interrupt process.
2.2.1.4 DRAM Management
The video controller uses DRAMs for the system RAM and for the V-RAM.
In this printer, four standard 512K
×
8bit DRAMs are mounted in locations IC18, IC19, IC20, and
IC21, providing a total of 2 MB. SIMM sockets number 1 (CN1) and number 2 (CN6) are optional
SIMM sockets. These SIMM sockets can use 1, 2, 4, 8, 16, 32 MB SIMM (32-bit bus).
The DRAMs (including optional SIMMs) are managed by the ASIC E05A91, which also outputs
MA0-10 (memory address), RAS/CAS, and DWE signals.
CAS0,1,2,3
DRAM
(IC18)
DRAM
(IC19)
DRAM
(IC20)
DRAM
(IC21)
DWE
RAS0
RAS1,2
RAS3,4
MA0-10
CPU DATA BUS
SIMM
Slot 1
(CN1)
SIMM
Slot 2
(CN6)
E05A91
(IC1)
Figure 2-31. DRAM Management
EPL-N1200 Service Manual
Operating Principles
Rev. A
2-21