Table 5-12. The LCD Displays Mem Overflow
Cause
Step
Checkpoint
Finding
Solution
The optional SIMM may be
bad.
1
Is operation OK after you
remove the optional SIMM?
Yes
Replace the SIMM.
Standard RAM may be bad.
2
—
—
Replace the C205
MAIN board.
Table 5-13. The LCD Displays SERVICE REQ. E0003
Cause
Step
Checkpoint
Finding
Solution
The connector for the
thermistor may be
disconnected.
1
Is the connector for the
thermistor disconnected?
Yes
Connect it.
The engine controller board
may be dead.
2
Does the heater lamp
remain lit up until an error
occurs?
Yes
Replace the
engine controller
board.
The heater lamp or thermal
fuse in fusing unit may be
bad.
3
Does the heater lamp come
on at power on?
No
Replace the heater
lamp or thermal
fuse in fusing unit.
The power supply board
may be dead.
4
—
—
Replace the power
supply board.
Troubleshooting