3.2.2.9 Main Motor Removal
1.
1.
Open the top cover. Remove the imaging cartridge. Cover the imaging cartridge to protect it
from light or place it in a dark area.
2.
Remove the main controller board. (Refer to Section 3.2.1.1.)
3.
3.
Loosen two CC (M3x8) screws which secure the right cover.
4.
Remove left and right tabs for the top cover from the printer base unit then remove the top
cover.
5.
Remove one CC (M3x6) screw on the fusing unit cover and remove the fusing unit cover.
6.
Remove four CP(O) (M3x6) screws on the rear panel unit.
7.
Disconnect connector for the paper exit sensor then lay the rear panel unit flat.
8.
Remove one CC (M3
×
6) screw from the control panel and lift the panel forward.
9.
Remove two CC (M3x8) screws on the paper guide case.
10.
10. Remove four CC (M3x6) screws on the top and two CC (M3x6) screws at the right of the shield
cover and take it away.
11.
11. Remove two CP(S)(P) (M4
×
6) screws for the main motor.
12. Lift the main motor, and disconnect connector for the main motor.
CP(S)(P)(M4X6)
Main Motor
Connector
Figure 3-22. Main Motor Removal
Disassembly and Assembly
EPL-N1200 Service Manual
3-18
Rev. A
Summary of Contents for EPL-N1200
Page 1: ...EPSON TERMINAL PRINTER EPL N1200 SERVICE MANUAL EPSON 4006838 ...
Page 8: ...REVISION SHEET I Revision I Issue Date Revision Page Rev A December 9 1996 1st issue vii ...
Page 111: ...Chapter 4 Adjustment No adjustment is required in this product ...
Page 127: ...6 ii Rev A ...
Page 133: ...Figure A 2 Engine Section Cable Connection Appendix A EPL N1200 Service Manual A 2 Rev A ...