Laser
Service Manual
Disassembly and
3.2.3.6
High Voltage Supply Board
Removal
1. Open the top
cover. Remove the imaging cartridge. Cover the imaging cartridge to protect it
from the light or place it a dark area.
2. Remove the control
(Refer to Section
3. Remove the paper cover.
4.
Remove therightcoverand left cover. (Refer to Section 3.2.2.)
5. Remove the top cover.
6. Remove the rear frame. (Refer to Section 3.2.2.2.)
7.
connectors
the red wire terminal, and the black wire terminal on the
high voltage supply board
8. Remove 3
screws
x 8) on the high voltage supply board, and remove the high voltage
supply board
CP
CP
X
8)
CN1
X
Red
Terminal
Black Wire Terminal
Figure
Removing the
High
Board
Rev.