Laser
Service Manual
5.4.2 Print Quality Anomaly
This section describes how to isolate a print quality problem from the possible causes.
Table 5-29. Print Quality Anomaly
Symptom
Possible Cause
Part Name
Check Item
Remedy
Low image density.
Shake the imaging
Imaging
Check the toner
Poor
cartridge
in the imaging
‘
-
cartridge.
Replace the imaging
development
cartridge.
board
—
Replace the PWBF
board.
Imaging
Replace the imaging
Improper
cartridge
—
cartridge.
charging
board
—
Replace the
board.
Check to see if the
Image transfer
surface of image
Replace the image
Image transfer
roller
transfer roller is
transfer roller.
problem
damaged.
board
—
Replace the
board.
Paper problem
Paper
Check to see if paper
is moist.
Defective
unit
‘
Replace the
unit
unit.
Improper print
Adjust the print
density setting
—
—
density using
level 2.
Foggy background
Replace the imaging
Imaging
—
cartridge.
development
. .
Check the wiring of
Replace the
developing bias line.
board.
Replace the
—
board.
Drum charge
charging
Check the wiring of
PC drum charging
Replace the imaging
bias line.
cartridge.
Improper print
Adjust the print
density setting in
—
—
density in
level 2
level 2.
Defective
unit
—
Replace the
unit
unit.
Rev.
S-11