1.2.2 Electrical Specifications
Table 1-6. Electrical Specifications
I
I
1
I
Description
I
100 V Version
I
200 V Version
I
Rated voltage
100-120
220-240
Input voltage range
90-132
198-264
,
,
Rated frequency range
50-60 Hz
Input frequency range
47-63 Hz
Rated current
5.5 A
3.3 A
Power consumption
Less than 600 W
I
1.2.3
Reliability Specifications
MPBF (Mean Prints Between Failures): Over 25,000 Sheets
Note:
indicates average number of pages printed before occurrence of problem requiring
replacement or
MTBF (Mean Time Between Failures):
Jam rate:
Feed failure:
Multiple paper feeds:
Paper curl height:
Leading edge
bending (1 cm or more):
(Mean Time To Repair):
Durability:
3000
Power on hours
1 out of
sheets or less (excluding
feeding)
1 out of 2,000 sheets or less (excluding multiple-sheet feeding)
1 out of 500 sheets or less
30 mm (1.2 inches) or less
1 out of 1,000 sheets
30 minutes or less
5 years or 180,0000 sheets
1.2.4 Environmental Conditions for Operating (Include Imaging Cartridge)
Temperature:
10to35‘C (50 to 95 ‘F)
Humidity:
15 to 85
Altitude:
m
feet) or lower
Levelness:
Printer should be installed on a level plane.
3,000 I
UX
or less (Must not be exposed to direct sunlight.)
Surrounding space:
Printer should have at least 100 mm clearance on its sides
and rear.
1.2.5 Environmental Conditions for Storage and
(Exclude Imaging Cartridge)
Temperature:
Oto35‘C (32 to 95 “F) over full storage term
-20 to55“C
to 131
“F) under extreme conditions
(Extremes are allowable for up to
full storage term)
Temperature variation must be10‘C (18 ‘F)
or less
Humidity:
30to85‘%oRH over full storage term
10 to 95
under extreme conditions
(Extremes are allowable for up to 1/30 of full storage term)
Drop test:
Clear to
Level 1
Vibration:
Vibration frequency
5 to
Hz and 100 5 Hz
Acceleration
3direction
Resistance to atmospheric pressure:
More than 613 mb
Storage term:
24
months
(following date of manufacture)
Rev.
1-7