Disassembly and Assembly
Laser 1000/1500 Service Manual
3.2.3.12 Paper Take-Up Roller Removal
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
Open the top cover. Remove the imaging cartridge. Cover the imaging cartridge to protect it
from the light or place it in a dark area.
Remove the control panel. (Refer to Section 3.2.1.3.)
Remove the paper cover,
Remove the left and right covers. (Refer to Section 3.2.2.1.)
Remove the top cover. (Refer to Section 3.2.2.1.)
Remove the rear frame. (Refer to Section 3.2.2.2.)
Remove the fusing unit. (Refer to Section 3.2.3.9.)
Remove the power supply unit. (Refer to Section 3.2.3.2.)
Remove the printhead unit. (Refer to Section 3.2.3.4.)
Remove the image transfer assembly. (Refer to Section 3.2.3 .11.)
comectors
CN3, the red wire terminal, and the black wire terminal on the
high voltage supply board
Remove the 2 CC screws
x
8) on the guide plate.
Remove the guide plate and the paper empty sensor flag.
Remove 2 CC screws
x 8) on
paper take-up assembly.
Slide the paper-take up assembly to the right, lift the left side up, and remove the paper
take-up assembly.
CC
X
cc
Figure 3-23. Removing the Paper Take-Up Assembly