a)
After the chiller has run for a minute without leaking, turn the chiller off and unplug it.
Add additional water to the chiller to accommodate for the water that was used to fill
the hoses and the laser tube. Secure the chiller’s water cap and plug in the chiller.
b)
The chiller temperature should be set at +/- 2 degrees C (+/- 5 degrees F) of the
ambient air temperature in the room where the laser is operating. 20 degrees C (70
Degrees F) is a standard setting for many office/warehouse type environments where
the laser is normally used.
Proper chiller temperature setting is essential to
preventing condensation and other damage to the laser
. The chiller manual
describes how to properly set the chiller temperature and how to set the chiller for C or
F settings.
10)
Plug in and turn on the Radius. The Radius power switch is located on the front, lower
right of the machine.
ALL MODELS
1)
Verify that the machine “beeps” and begins moving. The lens carriage will slowly move
into the home position, and the display will show the word “OFFLINE” if everything is
okay.
2)
Press the “focus” key, and with your finger spin the black knob on the keyboard clockwise
until the table is all the way up. It will stop by itself at the limit of travel.
3)
Reach under the table and remove the two foam shipping supports.
CONNECTING THE EXHAUST
7
The exhaust system should be installed by a contractor prior to the arrival of the Epilog
installation technician. The blower should be mounted outside your building for noise
considerations. The blower should not be more than twenty feet from the Radius. You should
provide a rigid, smooth 6” duct from the blower to the vicinity of the Radius. The Radius
requires 400 CFM at 6” of pressure. Remember to put the blower switch in an obvious place