rectangular cutout. Mate the larger end of the printer cable to the Radius. The connector
can be connected only one way. Close the wire retainer clips around the ends of the cable.
2)
Connect the other end of the cable to the LPT (parallel printer) connector on your
computer.
25/30 WATT ONLY
1)Locate the “Power” label on the back of the machine. The label is located in the center of the
back panel. The label indicates whether the machine is wired for 120 or 240 volts. Please
verify that the machine is the correct voltage for your building. Do not proceed if the voltage is
incorrect. Call Epilog technical support.
2)Locate the power cord in the accessory kit. One end will have the familiar three prong plug
for a wall power outlet. Plug the other end into the power receptacle on the back panel of the
Radius. The receptacle is located on a recessed panel in the center of the machine, below the
voltage label.
3)Plug the machine into your wall power outlet, and turn the machine on. The power switch is
on the front of the machine, lower right corner.
50 & 100 WATT ONLY
The Radius requires 208-240 VAC, single phase. Building wiring must be performed by a
licensed electrician if not already available, and must be done prior to the arrival of the Epilog
installation technician. Two 15 amp circuits must be provided. One for the Radius and one for
the chiller. Each with a NEMA L6-15R receptacle (HUBBEL 4560 or equivalent)
1)
Unpack the chiller by cutting the straps securing it to the pallet. Remove the packing
material.
2)
Lift the chiller off the pallet. The chiller is heavy, and at least two people will be required.
Be careful not to lift beyond your ability, or to drop the chiller on a foot or toe.
3)
Locate the chiller hoses from your accessory kit. There will be a bag with clear tubing and
clamps.
4)
Roll the chiller along the left side (looking from the front) of the Radius, with the chiller
water connections facing the rear.
5)
Slip two hose clamps onto the first hose, then connect one end to the chiller “outlet” and
the other to the Radius “coolant water in”. The water chiller connections on the Radius are
located in a cutout on the rear corner of the machine. Push the hose all the way onto the
barbs, and then slide the clamps over the barbs and tighten them.
6)
Repeat for the other hose. These will be marked “inlet” on the chiller and “coolant water
out” on the Radius.
7)
Fill the chiller with tap water, remembering to secure the chiller’s water cap.
8)
Plug the chiller into one of the 208-240VAC single phase receptacles.
9)
Turn the chiller on. Let the chiller water circulate through the hoses for one minute.
Check for any leaks. If you notice any leaks, immediately TURN OFF then UNPLUG the
chiller. With the chiller unplugged, tighten the leaking fitting.
6