These functions can be set by entering the appropriate code, by going to the
symbol in the
main menu and pressing the jog-dial button for approx. 6-7 seconds and then entering one of the
codes from the „PFC codes“ table.
An „AND“ in the switching conditions means that these conditions must be met at the same time.
Additional functions of the potential-free output PFC
Code Switching operation
7000 PFC operates as it is set in the service level menu (PFC = off, PFC = coupled with sauna
on / off, PFC = can be switched manually in the user settings menu)
7001 PFC closes, when the cabin light is switched on and opens when the cabin light is swit-
ched off
7002 PFC closes, when the cabin light is switched off and opens when the cabin light is swit-
ched on
7003 PFC closed, when the sauna is switched on AND there is no fault, otherwise open.
The normal (already existing) coupling of the PFC with the sauna-on function does not
take any interference into account.
PFC opens when the sauna is switched off or in after heating mode.
Application: PFC closes when the sauna is on and runs without a fault shut-down.
7004 PFC closes if any fault is present.
The fault is saved until the next time the sauna is switched on without a fault.
Application: Fault collecting line to PFC
7005 PFC closed, when the sauna is switched on AND when there is no fault AND when steam
production is requested, otherwise open.
To avoid that the heater is throttled to 2/3 of its power output when steam is requested,
as is the case with a heater with an integrated vaporizer, the active code 7005 will disa-
ble the WB output and also the WM water shortage input.
Application: Connection of an external vaporizer to PFC instead of WB/WM connection.
7006 PFC closed, when the sauna is switched on AND if the cabin is heated up to pre-set level,
otherwise open.
PFC opens when the sauna is switched off or in after-heating mode.
Application: An external device shall be switched once the sauna reaches pre-set level.
7007 PFC closed, when the sauna is switched on AND the heater is heating, otherwise open.
Application: An external device shall be only switched if the heating is on and the heater
indeed heats (gets power).
7008 PFC closed, when sauna is switched on AND when ECO is active, otherwise open.
Application: An external device shall be switched when ECO mode is active.