16
EN
180 mm
210 mm
180 mm
210 mm
bottom mounting holes
Fig. 4
Fig. 3
Fig. 5
A. Mains cable, cables for heating, light etc.
B. Low-voltage lines, e.g. sensor, S-Bus lines.
top mounting hole
4. Open the relay box conduits for the lines.
5. Insert supplied rubber grommets into the
openings of the lower part of the housing.
6. Route the connecting cables through the
openings.
A
B
7. Hook the relay box into the upper screw using
the upper mounting hole.
8. Securely tighten the relay box using the two lo-
wer mounting holes.
• Once you have completed all installation work
you can connect the consumers and plug in
the lines.
• Connect the data cables (sauna bus / sensor
bus lines - see also Electric Connections).
• Connect and configure the electric consu-
mers (see also Electric Connections).
9. Finally close the housing with the front covers
and secure them with 6 screws.