43
EN
The control unit is factory set to inductive lighting load. Hence, resistive loads can also be con-
trolled. If required, the light output can also be switched manually to capacitive loads.
When using incandescent lamps, the lighting load must remain set to inductive load.
The current setting is shown on the display.
Set lighting load to resistive load
• If applicable, open the housing of the power unit.
• Check whether the power unit is disconnected from the power supply.
• Disconnect the light on the main board.
• Switch on power unit and control panel.
• Press
5 sec.
.
• Enter code and confirm.
Code
Einstellung
Code
20:51
8001
• Disconnect the power unit from the mains and reconnect the lamp.
• Close the housing.
• Restore the power supply and switch the power unit back on.
20:51
55%
Licht
R, L
Einstellung
Helligkeit
indication of light type setting
R, L
Inductive / resistive load
when using incandescent lamps
factory setting
R, C
Capacitive load
electronic ballasts for reverse phase control
Code
8001
Code
8002
Code
8001
: Inductive / resistive load, when using
incandescent lamps
Code
8002
: Capacitive load, electronic ballasts for
reverse phase control
Manual setting of the lamp
NOTICE
Material damage
Improper settings can damage the device. In this case, the warranty expires.
• The work may only be carried out by a trained specialist from an authorised electrical com-
pany.