36
Installation Instructions - EmoTouch 3
Electrical installation
EN
5.1 Circuit board assignment
The sauna heater, cabin lighting, fan and module are connected via the
relay box. All connected modules are controlled by the control panel.
Schematic view of connections
In addition to the control panel, another module can be connected to the
B
jacks for the sauna bus.
A
Circuit board for relay box (diagram)
B
Sauna bus
C
Sensor bus
D
Reserve
E
Humidity sensor
F
Bench sensor
G
Heater sensor and safety
temperature limiter
H
EmoTouch 3 control panel
I
Cabin lighting
J
Fan
K
Circuit breaker
L
Vaporiser
M
Sauna heater
- - -
optional
STB
PE
P max. 9 kW
Wb PE
Wm N
fan
light
L N L N
N
L1 L2 L3
L1 L2 L3 N W V U N
N
WB
WM
3 4
S1 S1 N
B
7/8
5/6
3/4
1/2
3x16A
STB
LSG
STB
M
B
A
C
D
E
H
G
F
L
K
J
I