EmoTouch 3 - Installation Instructions
25
Mounting
NOTICE
Electronics malfunctions
Routing data and power supply lines together can lead to elec-
tronics malfunctions because, e.g. because the sensor will not be
detected.
Do not route sensor and sauna bus lines together with power
supply lines.
Route cable conduits separately.
Line routing
Diagram – routing of data and control line(s)
The power supply, S-Bus and sensor lines can be routed to the relay box as
follows:
The lines can be routed along the outer wall of the cabin. They are then
passed into the housing from below. If they are not routed through a
cable conduit or a duct, they must be secured so they cannot be pulled
out.
The cables can be routed between the insulation and the outer wall of
the cabin. They are then passed into the housing from the rear.
In both cases, the cabin insulation must be installed in such a way that the
temperature in the area in which cables are routed cannot exceed 75°C.
A
Insulation
B
Inner wall of the cabin
C
Outer wall of the cabin
D
Connecting lines
C
A
B
A
B
D
D
C