EmoTouch 3 - Installation Instructions
51
Commissioning
10
Open skin selection by pressing
.
11
Select the skin and confirm.
12
Select the sauna heater display and confirm.
After selecting the heater display, the selection of the connected
modules is displayed again.
If the installation is a multi-cabin installation, the skin, the heater
display and the module for each cabin is set.
6.3 Defining the light source manually
The control unit is set to inductive loads by the factory so that resistive
loads can also be controlled by the control panel. If required, the light out-
put can also be manually set to capacitive loads. For this, the lighting must
be disconnected.
If light bulbs are used, the load for lighting must remain as an inductive
load.
The current setting is shown on the display when the lighting is dimmed.
IR
Settings
Skin selection
Cabin 1
01. June 2019
10:32:14
Display symbol Setting
Code
Inductive/resistive load (lighting for phase con-
trol),
if light bulbs are used.
Factory setting
8001
Capacitive load (lighting for phase control)
Electrical ballasts for phase-cut dimmer
8002
R,L
R,C