EmoTouch 3 - Installation Instructions
39
Electrical installation
5.2.2 Terminals
All lines must be connected to the corresponding terminals. Heat-resistant
cables must be used for the light, fan, and vaporiser connections.
Safety temperature limiter
NOTICE
Equipment damage due to improper installation
Additional modules can be mounted in a cabin.
Connect the safety temperature limiter only to the relay box.
Always connect the safety temperature limiter as an isolated
contact.
If the installation uses multiple sauna heaters, multiple safety
temperature limiters may be required. Observe the separate
EOS instructions.
The safety temperature limiter's white cable from the main sensor (heater
sensor) is connected to the safety temperature limiter terminals.
Safety temperature limiter connection
Light and fan
The terminals for
light
and
fan
may each be occupied by one cable.
Connection for light and fan
The terminals for
light
may be used only for cabin lighting.
A fan with 5 W to 150 W may be connected to the
fan
terminal. The fan may
not have a starting capacitor.
Fan and light connections are protected by a joint 2AF fuse.
STB
fan
light
FL FN LL LN
L1 L2 L3 N W V U N
N
WB
WM
3 4
S1 S1 N
M A I N S
O V E N
V A P.
STB
fan
light
FL FN LL LN
L1 L2 L3 N W V U N
N
WB
WM
3 4
S1 S1 N
M A I N S
O V E N
V A P.