37742-0-1116
Page 17
Figure 25
COMPONENT WIRING DIAGRAM
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED
WITH THIS UNIT MUST BE REPLACED, IT MUST
BE REPLACED WITH EQUIVALENT GAUGE AND
TEMPERATURE RATED WIRE.
SI LE FIL ORIGINAL L'UN DES COMME FOURNI
AVEC CETTE UNITÉ DOIT ÊTRE REMPLACÉ, IL
DOIT REPLCED AVEC LA MESURE ÉQUIVALENTE
ET LE FIL ÉVALUÉ PAR TEMPÉRATURE.
ORANGE
PILOT
GAS CONTROL VALVE
ORANGE
GREEN
YELLOW
WHITE
BLACK
WHITE
BLOWER
FUSE
BLACK
WHITE
GREEN
TO JUNCTION
BOX
AUX.
LOOP
TO LIGHTS
SPLIT FLOW SOLENOID
SLEEVE
USER INTERFACE/
BATTERY HOLDER
L
N
COMBUSTION
BLOWER
A
D
E
B
C
INDEX NUMBER
DESCRIPTION
PART NUMBER
A
WIRE HARNESS, ACCENT LIGHT TERMINATION
R12269
B
WIRE ASSEMBLY, MODULE TO INTERFACE
R11552
C
WIRE HARNESS, PROFLAME2
R11551
D
WIRE ASSEMBLY (BLOWER)
R12256
E
WIRE HARNESS, MODULE TO JUNCTION BOX
R11730
Top of Receiver Module
Figure 26
Bottom of Receiver Module
Figure 27
Summary of Contents for DVCT36CFP95-1
Page 37: ...37742 0 1116 Page 37 LOG AND EMBER PLACEMENT 1 Place Ember Bed A onto burner pins 3 and 4 ...
Page 38: ...37742 0 1116 Page 38 LOG PLACEMENT 2 Place Log B onto burner pins 1 and 2 ...
Page 43: ...37742 0 1116 Page 43 LOG PLACEMENT 7 Place Log E onto burner pin 5 and the pin on Ember Bed A ...