37742-0-1116
Page 18
INSTALLATION
INSTALLATION TABLE - MINIMUM DIMENSIONS (in inches)
MODEL
A
B
C
D
E
F
DVCT36CFP
51 1/2
45 1/2
22 1/8
54 11/16
77-3/8
38 11/16
DVCT40CFP
53 1/2
49 1/2
24
59 11/16
84-3/8
42 1/4
C
A
B
Rough Opening for Floor Level Installation
Figure 28
A
C
B
Rough Opening for Elevated Installation
Figure 29
Rough Opening for Installing in Corner
Figure 30
The fireplace can be mounted on any of the following surfaces:
1. A flat, hard combustible or non-combustible surface.
2. A raised wooden platform.
3. Four corner supports. (Example: Four concrete masonry
blocks.) These supports must be positioned so they contact
all four perimeter edges on the bottom of the fireplace, if
allowed by local codes.
NOTICE:
Verify the gas supply and electrical considerations
before beginning the framing.
Framing Information
Fireplace framing can be built before or after the fireplace is set
in place. Position framing to accommodate wall covering and
fireplace facing material. Construct the fireplace framing with
2 x 4 lumber or heavier. Refer to the
INSTALLATION TABLE
below
for minimum framing dimensions.
CAUTION
Before construction begins, measure fireplace dimensions and
verify framing methods and wall covering details.
Summary of Contents for DVCT36CFP95-1
Page 37: ...37742 0 1116 Page 37 LOG AND EMBER PLACEMENT 1 Place Ember Bed A onto burner pins 3 and 4 ...
Page 38: ...37742 0 1116 Page 38 LOG PLACEMENT 2 Place Log B onto burner pins 1 and 2 ...
Page 43: ...37742 0 1116 Page 43 LOG PLACEMENT 7 Place Log E onto burner pin 5 and the pin on Ember Bed A ...
Page 55: ...37742 0 1116 Page 55 THIS PAGE IS INTENTIALLY LEFT BLANK ...