AIR SHUTTER ADJUSTMENT
This Unit Is Equipped With Adjustable Air Shutters (2).
The air shuttters may be adjusted externally while unit is burning.
The unit is sent out with the recommended setting, but may need
to be fine tuned by installer.
NOTE: Fireplace must be turned off and cool to the touch
before proceeding.
1. Remove barrier screen and glass door. See maintenance and
service section of this manual.
(Figure 75)
Figure 75
2. Loosen screws (2) that lock the air shutter handles.
(Figure 76)
Loosen (2) air shutter handle screws
Figure 76
3. Replace glass door. See maintenance and service section of
this manual.
4. Turn unit on, see operating instructions in home owner’s
instructions, allow unit to warm up from 15-30 minutes to obtain
it’s full flame appearance.
5. You may now adjust the air shutters. The right air shutter handle
adjusts the front air shutter and the left air shutter handle adjusts
the rear air shutter. Slide the air shutter handle towards the right
to open and to the left to close.
(See Figure 77 Below)
Rear
Front
Close
Open
Figure 77
6. Turn off unit and allow to cool before replacing the barrier screen.
See maintenance and service section of this manual.