VERTICAL TERMINATION
No Elbows
DIMENSIONS
(In Feet)
MINIMUM
MAXIMUM
10
40
Figure 60
GENERIC MODEL SHOWN
Two 90° Elbows
EXAMPLE VENT RUNS
INITIAL PIPE
LENGTH
(In Inches)
A-Vertical
(In Feet)
B-Horizontal
(In Feet)
12
34
3
24
30
6
36
25
9
48
20
12
*Maximum horizontal run is 100% of vertical, but cannot
exceed 18 ft.
Figure 61
GENERIC MODEL SHOWN
Three 90° Elbows
NOTE
: Subtract 3 feet from the total horizontal measurement for
each 90° elbow installed horizontally. Subtract 1-1/2 feet from
the total horizontal measurement for each 45° elbow installed
horizontally.
EXAMPLE VENT RUNS
INITIAL PIPE
LENGTH
(In Inches)
A-Vertical
(In Feet)
B-Horizontal
(In Feet)
12
31
3
24
27
6
36
22
9
48
17
12
*Maximum horizontal run is 100% of vertical, but cannot exceed
18 ft.
Figure 62
GENERIC MODEL SHOWN