37742-0-1116
Page 11
BLOWER INSTALLATION
3. Remove burner base.
(Figure 8)
Figure 8
4. Remove Blower Brackets by taking out (6) screws each.
(Figure 9)
Figure 9
5. Place Blower onto Blower Brackets.
(Figure 10)
.
Figure 10
6. Bend tab as shown in
(Figure 11)
and secure with
(2) screws.
HAND BEND
TAB INWARD
HAND BEND
TAB INWARD
Figure 11
7. Remove protective connectors on Wire Assembly from
fireplace and discard. Connect Wire Harness to both blowers
and the other end to the Wire Assembly supplied with the
fireplace.
(Figure 12)
TO WIRE ASSEMBLY
(MODULE)
TO WIRE ASSEMBLY
(MODULE)
Figure 12
8. Replace Blower Bracket (w/ blowers attached) with (6)
screws each.
(Figure 13)
Figure 13
9. Replace Glass Frame, Screen Barrier, and liners removed in
Step 1
(Figure 6).
Summary of Contents for DVCT36CFP95-1
Page 37: ...37742 0 1116 Page 37 LOG AND EMBER PLACEMENT 1 Place Ember Bed A onto burner pins 3 and 4 ...
Page 38: ...37742 0 1116 Page 38 LOG PLACEMENT 2 Place Log B onto burner pins 1 and 2 ...
Page 43: ...37742 0 1116 Page 43 LOG PLACEMENT 7 Place Log E onto burner pin 5 and the pin on Ember Bed A ...
Page 55: ...37742 0 1116 Page 55 THIS PAGE IS INTENTIALLY LEFT BLANK ...