NOTE:
When installing this
appliance against an exterior wall,
insulate to applicable insulation
codes.
LOCATING FIREPLACE
CORNER
INSTALLATION
ANGLED CORNER
INSTALLATION
ISLAND
INSTALLATION
CABINET
INSTALLATION
FLUSH WALL
INSTALLATION
ROOM DIVIDER
INSTALLATION
ELECTRICAL CONSIDERATIONS
Junction Box
A factory-installed junction box is located on the lower right side of
the fireplace. Wiring must be fed to the junction box and attached
with wire nuts to the control module power leads already fed into
the junction box.
Attach black to black and white to white. The ground wire should
be attached to the ground on the junction box.
(Figure 23)
Interface/Battery Holder
The user interface/battery holder must be mounted within a distance
allowed by the attached 12 foot harness. As shipped, this harness is
already fed through a strain relief on the bottom of the component
access box and is attached to the User Interface/Battery Holder.
NOTE:
If an auxiliary device is to be used, its wiring may be fed
through the junction box strain relief. Auxiliary device amperage
limit is 5 amps.
NOTE:
A one inch diameter hole should be use to pass wiring through
studs.
BLACK (HOT)
JUNCTION BOX
WHITE (NEUTRAL)
GROUND TO JUNCTION BOX
120 VOLT POWER SUPPLY
JUNCTION BOX CONNECTIONS
Figure 23
CAUTION
All wiring should be done by a qualified electrician and shall be in compliance with all local, city and state building codes. Before making
the electrical connection, make sure that the main power supply is disconnected. The appliance, when installed, must be electrically
grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/NFPA 70 (Latest Edition).
VERTICAL
FRAMING
MEMBER
USER INTERFACE
HARNESS
USER INTERFACE/
BATTERY HOLDER
MUST BE INSTALLED
INTO WALL JUNCTION
BOX. (ORANGE LOW-
VOLTAGE BOX
RECOMMENDED.)
COMPONENT
ACCESS BOX
ELECTRICAL POWER TO UNIT
JUNCTION BOX / CONTROL MODULE
Figure 22
NOTE:
Island and Room Divider
installation is possible as long
as the horizontal portion of the
vent system does not exceed 18
feet with a minimum vertical run
of 8 feet. See details in Venting
Section.
When you install your Direct Vent
Fireplace in room divider or flat
on wall corner positions, maintain
a minimum of 6 inches between
the perpendicular wall and the
opening of the appliance.
Figure 24
Summary of Contents for DVCT36CFP95-1
Page 37: ...37742 0 1116 Page 37 LOG AND EMBER PLACEMENT 1 Place Ember Bed A onto burner pins 3 and 4 ...
Page 38: ...37742 0 1116 Page 38 LOG PLACEMENT 2 Place Log B onto burner pins 1 and 2 ...
Page 43: ...37742 0 1116 Page 43 LOG PLACEMENT 7 Place Log E onto burner pin 5 and the pin on Ember Bed A ...
Page 55: ...37742 0 1116 Page 55 THIS PAGE IS INTENTIALLY LEFT BLANK ...