VERTICAL, 90 DEGREE ELBOW TO HORIZONTAL
OUT THE WALL
(12 inch minimum rise before elbow)
WALL FIRESTOP/
THIMBLE/SPACER
A
DIMENSION
A
B
C
6”
12 1/2
4 3/4
9”
15 1/2
4 3/4
12”
18 1/2
4 3/4
Figure 37
CORNER INSTALLATION - VERTICAL, 90 DEGREE ELBOW
TO HORIZONTAL OUT THE WALL
(12 inch minimum rise before elbow)
WALL FIRESTOP/
THIMBLE/SPACER
VENT
CAP
6”
MINIMUM
9”
MINIMUM
D
B
A
C
DIMENSION
DVCT36
DVCT40
A
54 1/16
59 11/16
B
38 11/16
42 1/4
C
19 1/4
20 5/16
D
77 7/8
84 3/8
Figure 38
VERTICAL, 90 DEGREE ELBOW WITH
HORIZONTAL TERMINATION
3” (76mm)
MINIMUM CLEARANCE
TO COMBUSTIBLES
VENT CAP/
THIMBLE
WALL FIRESTOP/
SPACER
A
DISTANCE
TO BOTTOM
OF UNIT
12” Rise
Required
NO COMBUSTIBLES
ALLOWED IN SHADED
AREA
Figure 39
DIMENSION
DVCT36
DVCT40
A
64
66
Note For DVCT36 Horizontal Vent Runs Only:
The wall thimble spacer and wall thimble should be used for
horizontal vent installations through combustible wall. The wall
thimble spacer should be sandwiched between the wall and the
inside half of the wall thimble refer.
See Figure 42.
The spacer
flanges are to point towards the wall.
Figure 40
INSTALLATION
INCLUDED:
WALL THIMBLE
SPACER
ATTACHED TO
SIDE OF UNIT
(DVCT36 ONLY)
Summary of Contents for DVCT36CFP95-1
Page 37: ...37742 0 1116 Page 37 LOG AND EMBER PLACEMENT 1 Place Ember Bed A onto burner pins 3 and 4 ...
Page 38: ...37742 0 1116 Page 38 LOG PLACEMENT 2 Place Log B onto burner pins 1 and 2 ...
Page 43: ...37742 0 1116 Page 43 LOG PLACEMENT 7 Place Log E onto burner pin 5 and the pin on Ember Bed A ...
Page 55: ...37742 0 1116 Page 55 THIS PAGE IS INTENTIALLY LEFT BLANK ...