CG Drives & Automation 01-7491-01r0
Operation via the Control Panel
91
10.3.1 The main menu
This section gives you a short description of the functions in
the Main Menu.
100
Start Window
Displayed at power-up. It displays the actual process value as
default. Programmable for many other read-outs.
200
Main Setup
Main settings to get the AC drive operable. The motor data
settings are the most important. Also option utility and
settings.
300
Process and Application
Parameters
Settings more relevant to the application such as Reference
Speed, torque limitations, PID control settings, etc.
400
Load Monitor and Process
Protection
The monitor function enables the AC drive to be used as a
load monitor to protect machines and processes against
mechanical overload and underload.
500
Inputs/Outputs and Virtual
Connections
All settings for inputs and outputs are entered here.
600
Logical Functions and Timers
All settings for conditional signals are entered here.
700
View Operation and Status
Viewing all the operational data like frequency, load, power,
current, etc.
800
View Trip Log
Viewing the last 10 trips in the trip memory.
900
System data
Electronic type label for viewing the software version and
AC drive type.
10.4 Programming during
operation
Most of the parameters can be changed during operation
without stopping the AC drive. Parameters that can not be
changed are marked with a lock symbol in the display.
10.5 Editing values in a menu
Most values in the third row in a menu can be changed in
two different ways. Enumerated values like the baud rate can
only be changed with alternative 1.
Alternative 1
When you press the + or - keys to change a value, the cursor
is flashing to the left in the display and the value is increased
or decreased when you press the appropriate key. If you keep
the + or - keys pressed, the value will increase or decrease
continuously. When you keep the key pressed the change
speed will increase. The Toggle key is used to change the
sign of the entered value. The sign of the value will also
change when zero is passed. Press Enter to confirm the value.
Alternative 2
Press the + or - key to enter edit mode. Then press the Prev
or Next key to move the cursor to the right most position of
the value that should be changed. The cursor will make the
selected character flashes. Move the cursor using the Prev or
Next keys. When you press the + or - keys, the character at
the cursor position will increase or decrease. This alternative
is suitable when you want to make large changes, i.e. from
2 s to 400 s.
To change the sign of the value, press the toggle key. This
makes it possible to enter negative values (Only valid for
certain parameters).
Example: When you press Next the 4 will flash.
Press Enter to save the setting and Esc to leave the edit
mode.
NOTE: If you try to change a function during
operation that only can be changed when the motor
is stopped, the message “Stop First” is displayed.
2621
0rpm
Baudrate
38400
Stp
Key/Key
331
0rpm
Acc Time
10.0s
Stp
Key/Key
331
0rpm
Acc Time
10.0s
Stp
Key/Key
Flashing
Summary of Contents for FDU Series
Page 1: ...Emotron FDU 2 1 AC drive Instruction manual English Valid from software version 5 00...
Page 2: ......
Page 4: ......
Page 10: ...6 CG Drives Automation 01 7491 01r0...
Page 50: ...46 Installation CG Drives Automation 01 7491 01r0...
Page 60: ...56 Control Connections CG Drives Automation 01 7491 01r0...
Page 64: ...60 Getting Started CG Drives Automation 01 7491 01r0...
Page 84: ...80 EMC and standards CG Drives Automation 01 7491 01r0...
Page 195: ...CG Drives Automation 01 7491 01r0 191...
Page 196: ...192 CG Drives Automation 01 7491 01r0...
Page 204: ...200 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 7491 01r0...
Page 219: ...CG Drives Automation 01 7491 01r0 Technical Data 215...
Page 254: ...250 Menu List CG Drives Automation 01 7491 01r0...
Page 259: ......