108
Functional description
CG Drives & Automation 01-7491-01r0
Prepare parameter Set when different Motor data
M1 - M4:
1. Select desired parameter Set to be set in [241] A - D.
2. Select “Motor Set [212]” if other than the default
Set M1.
3. Set relevant motor data in the Menu group [220].
4. Set other desired parameter settings to belong to
this parameter Set.
To prepare a Set for another motor, repeat these steps.
This function copies the content of a parameter set into
another parameter set.
A>B means that the content of parameter set A is copied
into parameter set B.
Load Default Values Into Set [243]
With this function three different levels (factory settings)
can be selected for the four parameter sets. When loading
the default settings, all changes made in the software are set
to factory settings. This function also includes selections for
loading default settings to the four different Motor Data
Sets.
242
Copy Set
Default:
A>B
A>B
0
Copy set A to set B
A>C
1
Copy set A to set C
A>D
2
Copy set A to set D
B>A
3
Copy set B to set A
B>C
4
Copy set B to set C
B>D
5
Copy set B to set D
C>A
6
Copy set C to set A
C>B
7
Copy set C to set B
C>D
8
Copy set C to set D
D>A
9
Copy set D to set A
D>B
10
Copy set D to set B
D>C
11
Copy set D to set C
NOTE: The actual value of menu [310] will not be
copied into the other set.
243
Default>Set
Default:
A
A
0
Only the selected parameter set will revert
to its default settings.
B
1
C
2
D
3
ABCD
4
All four parameter sets will revert to the
default settings.
Factory
5
All settings, except [211], [221]-[228],
[261] and [923], will revert to the default
settings.
M1
6
Only the selected motor set will revert to
its default settings.
M2
7
M3
8
M4
9
M1M2M3
M4
10
All four motor sets will revert to default
settings.
NOTE: Trip log hour counter and other VIEW ONLY
menus are not regarded as settings and will be
unaffected.
NOTE: If “Factory” is selected, the message “Sure?”
is displayed. Press the + key to display “Yes” and
then Enter to confirm.
NOTE: The parameters in menu “[220] Motor data”,
are not affected by loading defaults when restoring
parameter sets A–D.
Summary of Contents for FDU Series
Page 1: ...Emotron FDU 2 1 AC drive Instruction manual English Valid from software version 5 00...
Page 2: ......
Page 4: ......
Page 10: ...6 CG Drives Automation 01 7491 01r0...
Page 50: ...46 Installation CG Drives Automation 01 7491 01r0...
Page 60: ...56 Control Connections CG Drives Automation 01 7491 01r0...
Page 64: ...60 Getting Started CG Drives Automation 01 7491 01r0...
Page 84: ...80 EMC and standards CG Drives Automation 01 7491 01r0...
Page 195: ...CG Drives Automation 01 7491 01r0 191...
Page 196: ...192 CG Drives Automation 01 7491 01r0...
Page 204: ...200 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 7491 01r0...
Page 219: ...CG Drives Automation 01 7491 01r0 Technical Data 215...
Page 254: ...250 Menu List CG Drives Automation 01 7491 01r0...
Page 259: ......