162
CG Drives & Automation 01-7491-01r0
Max Alarm
20
The max alarm level has been
reached.
Max PreAlarm 21
The max pre alarm level has been
reached.
Min Alarm
22
The min alarm level has been
reached.
Min PreAlarm 23
The min pre alarm Level has been
reached.
CA1
24
Analogue comparator 1 output.
CA2
25
Analogue comparator 2 output.
CA3
26
Analogue comparator 3 output.
CA4
27
Analogue comparator 4 output.
L1
28
Logic 1 expression output
L2
29
Logic 2 expression output
L3
30
Logic 3 expression output
L4
31
Logic 4 expression output
F1
32
Flip flop 1 output
F2
33
Flip flop 2 output
F3
34
Flip flop 3 output
F4
35
Flip flop 4 output
Operation
36
Run command is active or AC drive
running. The signal can be used to
control the mains contactor if the AC
drive is equipped with Standby
supply option.
T1Q
37
Timer 1 output
T2Q
38
Timer 2 output.
T3Q
39
Timer 3 output
T4Q
40
Timer 4 output
Sleeping
41
Sleeping function activated
PumpSlave1
43
Activate pump slave 1
PumpSlave2
44
Activate pump slave 2
PumpSlave3
45
Activate pump slave 3
PumpSlave4
46
Activate pump slave 4
PumpSlave5
47
Activate pump slave 5
PumpSlave6
48
Activate pump slave 6
PumpMaster1 49
Activate pump master 1
PumpMaster2 50
Activate pump master 2
PumpMaster3 51
Activate pump master 3
PumpMaster4 52
Activate pump master 4
PumpMaster5 53
Activate pump master 5
PumpMaster6 54
Activate pump master 6
All Pumps
55
All pumps are running
Only Master
56
Only the master is running
Loc/Rem
57
Local/Rem mode indication
Local = 1, Remote = 0
Standby
58
Standby supply option is active
PTC Trip
59
Trip when function is active
PT100 Trip
60
Trip when function is active
Overvolt
61
Overvoltage due to high main voltage
Overvolt G
62
Overvoltage due to generation mode
Overvolt D
63
Overvoltage due to deceleration
Acc
64
Acceleration along the acc. ramp
Dec
65
Deceleration along the dec. ramp
I
2
t
66
I
2
t limit protection active
V-Limit
67
Overvoltage limit function active
C-Limit
68
Overcurrent limit function active
Overtemp
69
Over temperature warning
Low voltage
70
Low voltage warning
DigIn 1
71
Digital input 1
DigIn 2
72
Digital input 2
DigIn 3
73
Digital input 3
DigIn 4
74
Digital input 4
DigIn 5
75
Digital input 5
DigIn 6
76
Digital input 6
DigIn 7
77
Digital input 7
DigIn 8
78
Digital input 8
ManRst Trip
79
Active trip that needs to be manually
reset
Com Error
80
Serial communication lost
External Fan
81
The AC drive requires external
cooling. Internal fans are active.
LC Pump
82
Activate liquid cooling pump
LC HE Fan
83
Activate liquid cooling heat
exchanger fan
LC Level
84
Liquid cooling low level signal active
RunR
85
Positive speed (>0.5%), i.e. forward/
clockwise direction.
RunL
86
Negative speed (<0.5%), i.e. reverse
counter clockwise direction.
Com Active
87
Fieldbus communication active.
Brk Fault
88
Tripped on brake fault (not released)
BrkNotEngage 89
Warning and continued operation
(keep torque) due to Brake not
engaged during stop.
Option
90
Failure occurred in built-in option
board.
NOT1
91
NOT gate 1 output
NOT2
92
NOT gate 2 output
NOT3
93
NOT gate 3 output
NOT4
94
NOT gate 4 output
NOT5
95
NOT gate 5 output
NOT6
96
NOT gate 6 output
Summary of Contents for FDU Series
Page 1: ...Emotron FDU 2 1 AC drive Instruction manual English Valid from software version 5 00...
Page 2: ......
Page 4: ......
Page 10: ...6 CG Drives Automation 01 7491 01r0...
Page 50: ...46 Installation CG Drives Automation 01 7491 01r0...
Page 60: ...56 Control Connections CG Drives Automation 01 7491 01r0...
Page 64: ...60 Getting Started CG Drives Automation 01 7491 01r0...
Page 84: ...80 EMC and standards CG Drives Automation 01 7491 01r0...
Page 195: ...CG Drives Automation 01 7491 01r0 191...
Page 196: ...192 CG Drives Automation 01 7491 01r0...
Page 204: ...200 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 7491 01r0...
Page 219: ...CG Drives Automation 01 7491 01r0 Technical Data 215...
Page 254: ...250 Menu List CG Drives Automation 01 7491 01r0...
Page 259: ......