82
Communication
CG Drives & Automation 01-7491-01r0
9.3
Motor data
Communication information for the different motors.
M1 contains parameters 43041 to 43048. The M2, M3, and
M4 contains the same type of information. For example
parameter 43043 in motor M1 contain the same type of
information as 44043 in M2.
9.4
Start and stop commands
Set start and stop commands via serial communication.
9.5
Reference signal
When menu “Reference Control [214]” is set to “Com” the
following parameter data should be used:
9.5.1 Process value
It is also possible to send the Process value feedback
signal over a bus (e.g. from a process or temperature sensor)
for use with PID Process controller [380].
Set menu “Process Source [321]” to F(Bus). Use following
parameter data for the process value:
Example:
(See Emotron Fielbus manual for detailed information)
We would like to control the AC drive over a bus system
using the first two bytes of the Basic Control Message by
setting menu “[2661] FB Signal 1” to 49972. Further, we
also want to transmit a 16 bit signed reference and a 16 bit
process value. This is done by setting menu
“[2662] FB Signal 2” to 42905 and menu “[2663] FB Signal
3” to 42906.
Motor
Modbus/
DeviceNet
Instance
number
Profibus
Slot/
Index
Profinet IO
index
EtherCAT
and
CANopen
index
(hex)
M1
43041–
43048
168/200
to
168/207
19425 -
19432
4be1 - 4be8
M2
44041–
44048
172/180
to
174/187
20425 -
20432
4fc9 - 4fd0
M3
45041–
45048
176/160
to
176/167
21425 -
21432
53b1 - 53b8
M4
46041–
46048
180/140
to
180/147
22425 -
22432
5799 - 57a0
Modbus/DeviceNet
Instance number
Function
42901
Reset
42902
Run, active together with either
RunR or RunL to
perform start.
42903
RunR
42904
RunL
Note! Bipolar reference mode is activated if both
RunR and RunL is active.
Default
0
Range
-16384 to 16384
Corresponding to
-100% to 100% ref
Communication information
Modbus /DeviceNet Instance number
42905
Profibus slot /Index
168/64
EtherCAT index (hex)
4b59
Profinet IO index
19289
Fieldbus format
Int
Modbus format
Int
Default
0
Range
-16384 to 16384
Corresponding to
-100% to 100% process value
Communication information
Modbus /DeviceNet Instance number
42906
Profibus slot /Index
168/65
EtherCAT index (hex)
4b5a
Profinet IO index
19290
Fieldbus format
Int
Modbus format
Int
NOTE! It is possible to view the transmitted process
value in control panel menu Operation [710]. The
presented value is depending on settings in menus
“Process Min [324]” and “Process Max [325]”.
Summary of Contents for FDU Series
Page 1: ...Emotron FDU 2 1 AC drive Instruction manual English Valid from software version 5 00...
Page 2: ......
Page 4: ......
Page 10: ...6 CG Drives Automation 01 7491 01r0...
Page 50: ...46 Installation CG Drives Automation 01 7491 01r0...
Page 60: ...56 Control Connections CG Drives Automation 01 7491 01r0...
Page 64: ...60 Getting Started CG Drives Automation 01 7491 01r0...
Page 84: ...80 EMC and standards CG Drives Automation 01 7491 01r0...
Page 195: ...CG Drives Automation 01 7491 01r0 191...
Page 196: ...192 CG Drives Automation 01 7491 01r0...
Page 204: ...200 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 7491 01r0...
Page 219: ...CG Drives Automation 01 7491 01r0 Technical Data 215...
Page 254: ...250 Menu List CG Drives Automation 01 7491 01r0...
Page 259: ......