Appendix II
EM12 User’s Manual
134
Code
Parameter Name
Setting range
Default
Property
b3-06 HDI function selection
15: Frequency source switchover
16: Switchover between main frequency source X and
preset frequency
17: Switchover between auxiliary frequency source Y
and preset frequency
18:Terminal 1 for Command source switchover
19: Terminal 2 for Command source switchover
20: Speed control/Torque control switchover
21: Torque control prohibited
22: PID pause
23: PID integral pause
24: Reverse PID action direction
25: PID parameter switchover
26: PLC status reset
27: Swing pause
28: Counter input
29: Counter reset
30: Length count input
31: Length reset
32: Pulse input (enabled only for HDI)
33: Frequency modification enable
34:Acceleration/Deceleration prohibited
35: Motor selection terminal 1
36: Motor selection terminal 2(reserve)
37: Fault reset
38: Normally open (NO) input of external fault
39: Normally closed (NC) input of external fault
40: User-defined fault 1
41: User-defined fault 2
42: Running pause
43: Free stop
44: Emergency stop
45: External STOP terminal 1
46: External STOP terminal 2
47: Deceleration DC braking
48: Immediate DC braking
49: Clear the current running time
32
★
b3-12 DI filter time
0.000s~1.000s
0.010s
☆
b3-13 Terminal command mode
0: Two-line mode 1
1: Two-line mode 2
2: Three-line mode 1
3: Three-line mode 2
0
★
b3-14
Rate of UP/DOWN
terminal
0.001Hz/s~65.535 Hz/s
1.000 Hz/s
☆
b3-15 DI1 ON delay time
0.0s~3000.0s
0.0s
☆
b3-16 DI1 OFF delay time
0.0s~3000.0s
0.0s
☆