5.Description of Function Codes
EM12 User's Manual
60
Setting Range
-100.0% ~100.0%
b5-11
AI1 input filter time
Default
0.01s
Setting Range
0.00s
~
10.00s
b5-12
AI2 input minimum value
Default
0.00V
Setting Range
0.00 V~10.00 V
b5-13
Corresponding setting of AI2 minimum input
Default
0.0%
Setting Range
-100.0% ~100.0%
b5-14
AI2 Maximum input value
Default
10.00V
Setting Range
0.00 V~10.00 V
b5-15
Corresponding setting of AI2 Maximum input value
Default
100%
Setting Range
-100.0% ~100.0%
b5-16
AI2 input filter time
Default
0.10s
Setting Range
0.00s~10.00s
b5-17
AI3 input minimum value
Default
-10.00V
Setting Range
-10.00V
~
10.00V
b5-18
Corresponding setting of AI3 minimum input
Default
0.0%
Setting Range
-100.0%
~
100.0%
b5-19
AI3 Maximum input value
Default
10.00V
Setting Range
0.00 V~10.00 V
b5-20
Corresponding setting of AI3 Maximum input value
Default
100.0%
Setting Range
-100.0%
~
100.0%
b5-21
AI3 input filter time
Default
0.10s
Setting Range
0.00s
~
10.00s
These parameters are used to define the relationship between the analog input voltage and the corresponding setting
value.
When the analog input is current input, 1 mA current corresponds to 0.5 Volts.
Diagram 5-21 Corresponding relationship between analog input and setting values