EM12 User’s Manual
Appendix I
125
Function code group
Communication inquiry address
Inquiry address When
Communication modifies RAM
A0~ A2
0xA000~ 0xA2FF
0x4000~ 0x42FF
b0~bC
0xA300~ 0xAFFF
0x4300~ 0x4FFF
C0~C6
0xb000~ 0xB7FF
0x5000~ 0x57FF
d0~d6
0xB800~ 0xBEFF
0x5800~ 0x5EFF
U0
0x7000~ 0x70FF
Besides, due to EEPROM be frequently stored, it will reduce the lifetime of EEPROM. In the communication
mode, and some function codes don’t have to be stored as long as change the RAM value.
Stop/start parameter
Parameter
address
Parameter description
Parameter
address
Parameter description
1000
Communication set value(-10000 ~
10000)(Decimal)
1010
PID setting
1001
Running frequency
1011
PID feedback
1002
DC Bus voltage
1012
PLC process
1003
Output voltage
1013
Pulse input frequency, unit: 0.01KHz
1004
Output current
1014
Feedback speed, unit:0.1Hz
1005
Output power
1015
Remaining running time
1006
Output torque
1016
Voltage before AI1correction
1007
Running speed
1017
Voltage before AI2correction
1008
DI input terminal
1018
Voltage before AI3correction
1009
DO output terminal
1019
Linear speed
100A
AI1 voltage
101A
Present power-on time
100B
AI2 voltage
101B
Present running time
100C
AI3 voltage
101C
Pulse input frequency, unit:1Hz
100D
Counting value input
101D
Communication setting value
100E
Length value input
101E
Actual feedback speed
100F
Load speed
101F
Main frequency X display
1020
Auxiliary frequency Y display
Note:
Communication setting value is the percentage of relative value, 10000 corresponds to 100%, -10000
correspond to -100.00%.
Control command input frequency inverter: (write in only)
Command word address
Command function
2000
0001: Forward running
0002: Reverse running
0003: Forward jog
0004: Reverse jog
0005: Free stop
0006:Decelarating stop
0007: Fault reset