Contacting conductivity
Table 2-5:
Measured range
0-20,000 µS/cm
Calibration
Calibration is easily accomplished by immersing the sensor in
a known solution and entering its value or entering the cell
constant for ultra-pure applications.
Automatic temperature compensation
3-wire Pt 100 or Pt 1000 RTd
Conductivity: 32 to 392 °F (0 to 200 °C)
Resistivity: 32 to 212 °F (0 to 100 °C)
Low conductivity: 32 to 212 °F (0 to 100 °C)
Accuracy
± 0.5% of reading and ±0.001 µS/cm
Repeatability
± 0.25% of reading
Stability
0.25% of output range/month, non-cumulative
Ambient temperature coefficient
± 0.05% of reading/°C
Temperature slope adjustment
0-5%/°C
Other temperature compensation algorithms
Ultra-pure water compensation
Cation conductivity
Raw (uncompensated) conductivity
Compatible RTD
100 Ohm or 1000 Ohm with automatic recognition
Toroidal conductivity
Table 2-6:
Measured range
50 to 2,000,000 µS/cm
Calibration
Calibration is easily accomplished by immersing the sensor in a
known solution and entering its value.
Automatic temperature compensation
3-wire Pt 100 RTD
Conductivity: 32 to 392 °F (0 to 200 °C)
% concentration: 32 to 212 °F (0 to 100 °C)
Accuracy
± 1.0% of reading
Repeatability
± 0.25% of reading
Stability
0.25% of output range/month, non-cumulative
Ambient temperature coefficient
± 0.2% of FS/°C
Temperature slope adjustment
0 - 5% / °C
% concentration ranges
Sodium hydroxide: 0 to 15%
Hydrochloric acid: 0 to 16%
Sulfuric acid: 0 to 25% and 96 to 99.7%
Dissolved oxygen
Table 2-7:
Measurement range
0 - 99 ppm (mg/L), 0 - 200 saturation
Resolution
0.01 ppm, 0.1 ppb for 499ATrDO sensor
Temperature correction for membrane permeability
Automatic between 0 and 50 °C (can be disabled)
Description and specifications
8
Rosemount 5081
Summary of Contents for Rosemount5081
Page 4: ......
Page 10: ...Contents vi Rosemount 5081 ...
Page 12: ...Startup procedure 2 Rosemount 5081 ...
Page 23: ...Mounting 5081 on a pipe Figure 3 2 Installation Instruction Manual 13 ...
Page 24: ...Installation 14 Rosemount 5081 ...
Page 28: ...Wiring 18 Rosemount 5081 ...
Page 50: ...Programming basics 40 Rosemount 5081 ...
Page 130: ...Diagnostics and troubleshooting 120 Rosemount 5081 ...
Page 136: ...Digital communications 126 Rosemount 5081 ...
Page 140: ...Engineering drawings 130 Rosemount 5081 ...
Page 141: ...Engineering drawings Instruction Manual 131 ...
Page 142: ...Engineering drawings 132 Rosemount 5081 ...
Page 143: ...Engineering drawings Instruction Manual 133 ...
Page 144: ...Engineering drawings 134 Rosemount 5081 ...
Page 145: ...Engineering drawings Instruction Manual 135 ...
Page 146: ...Engineering drawings 136 Rosemount 5081 ...
Page 151: ...EU Declarations of Conformity 138 Rosemount 5081 ...