WARNING
CRUSHING HAZARD
Do not remove flange stabilizers.
Attempting to do so could allow the meter to roll, resulting in serious injury or equipment
damage.
A. Flange stabilizers
WARNING
FLUID CONTENTS MAY BE UNDER PRESSURE
When the meter is under pressure, DO NOT attempt to remove or adjust the transducer
holder of the T-Slot transducer assembly, or loosen the screws holding the T-200
transducer assembly.
Attempting to do so could release pressurized gas or fluid, resulting in serious injury or
equipment damage.
WARNING
CONTENTS MAY BE HAZARDOUS
The meter must be fully depressurized and drained before attempting to remove the
T-200 transducer assembly. If gas or fluid begins to leak from the T-200 transducer stalk
assembly, stop immediately and reinstall T-200 stalk assembly.
Failure to comply could cause serious injury or equipment damage.
A. Transducer holder
CAUTION
ESCAPING GASES OR FLUIDS HAZARD
The purchaser of the meter is responsible for the selection of Rosemount
™
components/
seals and materials compatible with the chemical properties of gas flow measurement.
Failure to select the suitable meter component/seals may cause escaping gases or liquids,
resulting in injury or equipment damage.
Meter repairs
Maintenance and Troubleshooting Manual
April 2022
00809-0600-3104