81
Reference Manual
00809-0100-4840, Rev CB
February 2015
Rosemount 3101 with glass filled nylon housing: 2.0 lb (0,9 kg)
Rosemount 3102 with glass filled nylon housing: 2.2 lb (1,0 kg)
Rosemount 3105 with glass filled nylon housing: 3.1 lb (1,4 kg)
A.1.7
Measuring
Temperature compensation
(1)
Rosemount 3101: Automatic Integral temperature compensation
Rosemount 3102:
Automatic Integral temperature compensation. Optional remote temperature sensor for
dynamic temperature compensation
Rosemount 3105:
Automatic Integral temperature compensation. Optional remote temperature sensor for
dynamic temperature compensation
A.1.8
Environment
Ambient temperature
(2)
Rosemount 3101:
–4 to 158 °F (–20 to 70 °C)
Rosemount 3102 and Rosemount 3105:
–40 to 158 °F (–40 to 70 °C)
Process temperature
Rosemount 3101:
–4 to 158 °F (–20 to 70 °C)
Rosemount 3102 and Rosemount 3105:
–22 to 158 °F (–30 to 70 °C)
Process pressure
–4 to 44 psi (–0,25 to 3,0 bar)