![Emerson Rosemount 3101 Reference Manual Download Page 164](http://html.mh-extra.com/html/emerson/rosemount-3101/rosemount-3101_reference-manual_104699164.webp)
152
Reference Manual
00809-0100-4840, Rev CB
Appendix F: Programming the 3102 and 3105 using HART
February 2015
Programming the 3102 and 3105 using HART
Table F-1. Standard Flow Profile Options
Hmax
Scale Factor
Power
Factor
20 mA Point
(1)
(1) Where entries do not say “(User)”, the 20 mA Point (Upper Range Value) is automatically set to the value in the meters (m) or feet/inches (ft./in.) column
depending on the selected Base Units. The 4 mA Point (Lower Range Value) is automatically set to 0.
Options
Flow Structures
(m)
(ft./in.)
(m
3
/hour)
(2)
(2) If the Base Units are meters (m), the flow units are m
3
/hour. Otherwise, flow units are gal/m (GPM). The gallons are US gallons.
(GPM)
(m)
(ft./in.)
3/2
Flume 3/2 flow law
N/A
N/A
(User)
(3)
(3) Where shown, “(User)” indicates that the user is required to input the appropriate data.
(User)
1.5
(User)
(User)
5/2
V-Notch 5/2 flow law
N/A
N/A
(User)
(User)
2.5
(User)
(User)
mann
Manning formula
N/A
N/A
(User)
(User)
(User)
N/A
N/A
PAr01
1-in. Parshall flume
0.75
2.5
217.3
151.7
1.55
17.9
87.3
PAr02
2-in. Parshall flume
0.75
2.5
434.6
303.4
1.55
50.7
215
PAr03
3-in. Parshall flume
0.75
2.5
635.5
445.2
1.547
125
516
PAr06
6-in. Parshall flume
0.75
2.5
1372
924.5
1.58
389
1750
PAr09
9 -in. Parshall flume
0.75
2.5
1927
1378
1.53
882
3980
PAr1
1-ft. Parshall flume
0.75
2.5
2487
1795
1.522
1610
7240
PAr1.5
1
1
/
2
-ft. Parshall flume
0.75
2.5
3803
2693
1.538
2440
11000
PAr2
2-ft. Parshall flume
0.75
2.5
5143
3590
1.550
3290
14900
PAr3
3-ft. Parshall flume
0.75
2.5
7863
5386
1.566
5010
22600
PAr4
4-ft. Parshall flume
0.75
2.5
10630
7181
1.578
6750
30500
PAr5
5-ft. Parshall flume
0.75
2.5
13440
8976
1.587
8510
38400
PAr6
6-ft. Parshall flume
0.75
2.5
16280
10770
1.595
10300
46400
PAr8
8-ft. Parshall flume
0.75
2.5
22010
14360
1.607
13900
62600
PAr10
10-ft. Parshall flume
0.75
2.5
26862
17672
1.6
20700
89200
FF01
(4)
(4) FF and FP flume options require the Base Units to be meters (m). See
"Changing the base units (on the 3102/3105)" on page 74
if a change of Base Units is
required.
Flume Flat 1 (m)
0.102
N/A
0.135
N/A
1.5
9
N/A
FF02
Flume Flat 2 (m)
0.191
N/A
0.178
N/A
1.5
36
N/A
FF03
Flume Flat 3 (m)
0.267
N/A
0.313
N/A
1.5
90
N/A
FF04
Flume Flat 4 (m)
0.406
N/A
0.542
N/A
1.5
360
N/A
FF05
Flume Flat 5 (m)
0.635
N/A
0.811
N/A
1.5
900
N/A
FF06
Flume Flat I
0.200
N/A
0.132
N/A
1.5
30
N/A
FF07
Flume Flat II
0.250
N/A
0.178
N/A
1.5
60
N/A
FF08
Flume Flat III
0.300
N/A
0.218
N/A
1.5
90
N/A
FF09
Flume Flat III bis
0.3333
N/A
0.328
N/A
1.5
200
N/A
FF10
Flume Flat III ter
0.400
N/A
0.272
N/A
1.5
200
N/A
FF11
Flume Flat IV
0.400
N/A
0.352
N/A
1.5
180
N/A
FF12
Flume Flat V
0.500
N/A
0.443
N/A
1.5
360
N/A
FF13
Flume Flat V bis
0.400
N/A
0.401
N/A
1.5
320
N/A
FF14
Flume Flat VI
0.540
N/A
0.499
N/A
1.5
720
N/A
FF15
Flume Flat VII
0.700
N/A
0.624
N/A
1.5
1080
N/A
FF16
Flume Flat VIII
0.600
N/A
0.881
N/A
1.5
1440
N/A
FF17
Flume Flat VIII bis
0.666
N/A
0.798
N/A
1.5
1500
N/A
FF18
Flume Flat IX
0.800
N/A
1.065
N/A
1.5
1800
N/A
FF19
Flume Flat IX bis
0.733
N/A
0.815
N/A
1.5
1700
N/A
FF20
Flume Flat X
0.867
N/A
1.322
N/A
1.5
3600
N/A
FF21
Flume Flat X bis
1.200
N/A
1.609
N/A
1.5
7500
N/A
FF22
Flume Flat X ter
0.959
N/A
1.065
N/A
1.5
3500
N/A
FF23
Flume Flat XI
1.200
N/A
1.651
N/A
1.5
7200
N/A
FP01
Flume Parabolic 1
0.200
N/A
0.399
N/A
2.3
20
N/A
FP02
Flume Parabolic 2
0.250
N/A
0.442
N/A
2.3
40
N/A
FP03
Flume Parabolic 3
0.310
N/A
0.464
N/A
2.2
90
N/A
FP04
Flume Parabolic 4
0.380
N/A
0.544
N/A
2.2
180
N/A
FP05
Flume Parabolic 5
0.460
N/A
0.619
N/A
2.1
360
N/A
FP06
Flume Parabolic 6
0.600
N/A
0.717
N/A
2.1
720
N/A
FP07
Flume Parabolic 7
0.800
N/A
0.772
N/A
2.1
1400
N/A
Summary of Contents for Rosemount 3101
Page 2: ......
Page 4: ...ii Reference Manual 00809 0100 4840 Rev CB Title Page February 2015 ...
Page 12: ...x Reference Manual 00809 0100 4840 Rev CB Contents February 2015 Contents ...
Page 34: ...22 Reference Manual 00809 0100 4840 Rev CB Section 3 Installation February 2015 Installation ...
Page 68: ...56 Reference Manual 00809 0100 4840 Rev CB Section 4 Starting up February 2015 Starting up ...
Page 236: ...224 Reference Manual 00809 0100 4840 Rev CB Index February 2015 Index ...
Page 237: ......
Page 238: ......
Page 239: ......