F.3.37
Target pulses (P044)
Target Pulses (P044) is the number of ultrasonic pulses in each burst sent from the transmitter
every second.
The factory default “Automatic” setting allows the transmitter to decide the number of pulses.
Alternatively, select a number in the range 4 to 32.
Note
See Pulses in Use (
) for the actual number of pulses used.
Field Communicator or AMS Device
Manager
To view or change the number of pulses
in a burst
1.
From the
Home
screen, select 2: Configure.
2.
Select 2: Manual Setup.
3.
Select 7: Advanced Processing (
3105
) or
Select 8: Advanced Processing (
3102
)
4.
Select 5: Set Target Pulses.
5.
Select 1: Target Pulses P044.
6.
If a change is required:
(a) Select a new setting, and then select “ENTER” to save it.
(b) Select “Send” or “Apply” to update the transmitter.
Rosemount 3490 Series Control Unit
To view or change the number of pulses
in a burst
1.
From the
Main Menu
screen, select SETUP.
2.
Select the transmitter (e.g. “Tx1: 3102”).
3.
Select ENGINEERING, and then select ADVANCED.
4.
Select Target Pulses.
5.
Follow the on-screen instructions to edit and save the new setting.
(Use the Enter (
) key if prompted to change mode to “off-line”).
6.
Select “Quit” to exit to the previous menu.
Fast Keys
2, 2, 7 [or 8], 5, 1
Target Pulses P044
AUTOMATIC
27
28
29
30
31
32
AUTOMATIC
AUTOMATIC
ENTER
ESC
(
Field Communicator Screen Shown
)
Target Pulses P043
Automatic
Esc=Quit =Edit
(
Rosemount 3491 Screen Shown
)
Summary of Contents for Rosemount 3101
Page 2: ......
Page 4: ...ii Reference Manual 00809 0100 4840 Rev CB Title Page February 2015 ...
Page 12: ...x Reference Manual 00809 0100 4840 Rev CB Contents February 2015 Contents ...
Page 34: ...22 Reference Manual 00809 0100 4840 Rev CB Section 3 Installation February 2015 Installation ...
Page 68: ...56 Reference Manual 00809 0100 4840 Rev CB Section 4 Starting up February 2015 Starting up ...
Page 236: ...224 Reference Manual 00809 0100 4840 Rev CB Index February 2015 Index ...
Page 237: ......
Page 238: ......
Page 239: ......