Tank Shape/NLP (P011) = “Horizontal Cyl Dome”
This Horizontal Cylinder With Domed Ends setting is applicable when volume measurements are
needed from a horizontally-oriented cylindrical tank with a constant diameter (see
for a cross-sectional view).
The volume is calculated from the live level measurement, the full volume of an ideal cylindrical
tank, and the diameter of that tank.
Setting-up Procedure for “Horizontal Cyl Dome”:
1.
Use the Tank Shape/NLP (P011) parameter to select “Horizontal Cyl Dome”.
2.
Enter the full volume into the PV Scale Factor parameter (
3.
Enter the tank diameter into the Profile Height / Power Factor parameter (
).
Summary of Contents for Rosemount 3101