202
Reference Manual
00809-0100-4840, Rev CB
Appendix F: Programming the 3102 and 3105 using HART
February 2015
Programming the 3102 and 3105 using HART
F.4.9
Echo success (D912)
This is a measure of the quality of the echo returned. It is a percentage indicating the success
rate achieved from the last ten pulse transmissions.
The success rate may fall below 100% due to the effect of extreme surface turbulence or stirrers,
which might return a surface echo that is then rejected by the transmitter.
A surface echo might be rejected because it is outside the allowed 'window', set-up to establish
the true liquid level. This rejects invalid readings on the principle that liquid levels do not change
very quickly (see “Lost Echo Delay” on
).
One rejected surface echo causes Echo Success to decrease by 10%, but a subsequent valid
surface echo increases the percentage by 10%. The transmitter is biased to ignore sudden liquid
level changes.
Field Communicator or AMS Device Manager
To view the echo success
1.
From the
Home
screen, select 3: Service Tools.
2.
Select 1: Alerts.
3.
Select 2: Diagnostic Data.
4.
Select 1: Target Data.
5.
Select 3: Success Rate D912.
6.
When finished, select EXIT to exit to the previous menu.
Rosemount 3490 Series Control Unit
To view the echo success
1.
From the
Main Menu
screen, select MONITOR.
2.
Select the transmitter (e.g. “Tx1: 3102”).
3.
Select DIAGNOSTICS
4.
Select Echo Success.
5.
When finished, use the ESC key to exit to the previous menu.
Fast Keys
3, 1, 2, 1, 3
Success Rate D912
100 %
EXIT
HELP
(
Field Communicator Screen Shown
)
Echo Success D912
100%
(
Rosemount 3491 Screen Shown
)
Summary of Contents for Rosemount 3101
Page 2: ......
Page 4: ...ii Reference Manual 00809 0100 4840 Rev CB Title Page February 2015 ...
Page 12: ...x Reference Manual 00809 0100 4840 Rev CB Contents February 2015 Contents ...
Page 34: ...22 Reference Manual 00809 0100 4840 Rev CB Section 3 Installation February 2015 Installation ...
Page 68: ...56 Reference Manual 00809 0100 4840 Rev CB Section 4 Starting up February 2015 Starting up ...
Page 236: ...224 Reference Manual 00809 0100 4840 Rev CB Index February 2015 Index ...
Page 237: ......
Page 238: ......
Page 239: ......